¦h¥\¯à°ª°Å¤O§¡½èÅͩվ÷

Silverson ­^°ê

¾A¥Î©ó¡G¹êÅç¡B¬ãµo 

Silverson's line of laboratory mixers are suitable for the widest variety of applications - mixing, emulsifying, homogenising, disintegrating, dissolving - and will process volumes from as little as 1 ml up to 12 liters with an efficiency and flexibility unmatched by other machines.

¦¹¨t¦C§t SL2 / SL2T «¬

SL2T«¬¡]¼Æ¦rÅã¥ÜÂà³t¡^
SL2«¬¡]¤£§t¼Æ¦rÅã¥ÜÂà³t¡^


°¨¹F¡G1/10HP
Âà³t¡G9000rpm
µ²ºc¡G316¤£ù׿û»s
¤â°Ê½Õ¾ã¤W¤U
³Æ¦hºØ§¡½èÅÍ©ÕÀY

¦¹¨t¦C§t L4R / L4RT «¬

L4RT«¬¡]¼Æ¦rÅã¥ÜÂà³t¡^
L4R«¬¡]¤£§t¼Æ¦rÅã¥ÜÂà³t¡^

°¨¹F¡G1/3HP
Âà³t¡G9000rpm
¾Þ§@Áu°ª§C¦Û°Ê½Õ¾ã 
3/6¾ã¤£ù׿û¤§Âà¶b»PÅÍ©ÕÀY
¤Ø¤o¡G300w/500D/930Hmm
on/off¶}ÃöµL¬qÅܳt¡A¥i¥ô·N½Õ¾ã

¥i¿ï¾Ü °t¥ó:      ¬Á¼þ²~®e¶q¦³1000¤Î500ml
¾A©ó¶ê¤Õ¨Å¤ÆÀY¡A°ª°Å¤O¤Î¤@¯ë¤À¸ÑÀY

sealed unit Mixers¾A¥Î©ó¡G

¯f²z¡B²Óµß¡B°Ê´Óª«ªº²Õ´¡B°©ÀY¡B°¨¹F¥ÎL4R¨Ó­×§ï¡A©ö©ó©î¸Ë¡A¦b¦w¥þª¬ºA¤U¡AÁ×§K·P¬V

22.5ml¥Î3/4"¨Å¤ÆÀY
25ml¥Î5/8"¨Å¤ÆÀY
7ml¥Î3/8"¨Å¤ÆÀY

¤£ù׿û®e¶q¦³1¤½¤É¡A2¤½¤É,ÁÙ¦³disposable vessels 1¤½¤É¨Ñ¿ï¾Ü

³Æ¦³¦hºØ¤À¸ÑÀY¡A¾A¥Î©ó¤£¦P¤§¼Ë«~¡G

1.¤@¯ë¤À¸ÑÀY
2. °ª°Å¤O¤À¸ÑÀY
3.¶ê¤Õ¨Å¤ÆÀY
4.Åͩթâ¦VÀY
5.±øª¬¤À¸ÑÀY
6. ¨¹®úÀY

Silverson Laboratory Mixers -- A Closer Look

±j¤j¾÷±ñ°Å¤O¡A¦b·¥µu®É¶¡¤º¥i±N¼Ë«~§¹¥þÅͩաB²V¦X¡B¤À´²¡B¨Å¤Æ¬O¤@³¡§¡½èªº¦nÀ°¤â¡D

The advantages of Silverson's high shear rotor/stator laboratory mixers over simple conventional stirrers or agitators stem from the multi-stage mixing/shearing action as materials are drawn through the specially designed Silverson workhead - the heart of every machine.

Stage 1. The high-speed rotation of the rotor blades within the precision machined mixing workhead exerts a powerful suction, drawing liquid and solid materials upwards from the bottom of the vessel and into the center of the workhead.

Lab Mixer - Step 1

Stage 2. Centrifugal force then drives materials towards the periphery of the workhead where they are subjected to a milling action in the precision machined clearance between the ends of the rotor blades and the inner wall of the stator.

Lab Mixer - Step 2

Stage 3. This is followed by intense hydraulic shear as the materials are forced, at high velocity, out through the perforations in the stator and circulated into the main body of the mix.

Lab Mixer - Step 3

Stage 4. The materials expelled from the head are projected radially at high speed towards the sides of the mixing vessel. At the same time, fresh material is continually drawn into the workhead maintaining the mixing cycle. The effect of the horizontal (radial) expulsion and suction into the head is to set up a circulation pattern that minimizes aeration caused by the disturbance of the liquid's surface.

Lab Mixer - Step 4