Tyler¤§·n¿z¾÷¤ô¥®¶Àú¡A¤W¤UºVÀ»¡A³t«×§Ö¡B®ÄªG©_¨Î¡A´X¤ÀÄÁ¤º«K¯à³B²z¦n§Aªº¼Ë«~
¡@
|
³W®æ RX-29
- ¤ô¥®¶Àú¨C¤ÀÄÁ278¤U¡A®¶´T
1"x0.75"
- ¤W¤UºVÀ»¨C¤ÀÄÁ150¤U¡Aºl¤l«¶q5Ibs
- ©w®É¾¹¡G0-99¤À
- °¨¹F¡G1/4hp,115V/60Hz
- ¥i©ñ¤CÓ¥þ°ª¡Aª½®| 8"¡B203mm¡B3"¡B100mm¤§¼Ð·Ç¿z¡A¤£»Ýªþ¥[¥ô¦ó¨ä¥L¸Ë¸m
- °jÂà³t 1750rpm
- ¥~³¡¤Ø¤o¡G711W x 533D635Hmm
- ªþ¦XISO9002ÃÒ©ú
| at
1750rpm, 60cycle current |
| «¬¸¹ |
³W®æ |
| RX-29
/ 110V |
8"
test sieves |
| RX-29-16
/ 220V |
8"
test sieves |
| RX-30
/ 110V |
12"
test sieves |
| RX-30-16
/ 220V |
12"
test sieves |
|
 |
- For test sieve analysis ranging in particle
size from 4" opening through 150 micron
(USA No. 100)
- Equipped to process both 8" and 12"
diameter test sieves
- Affordable and has quiet operation
- Digital 99-minute clock/timer control,
accurate to .1 second, is standard
|
|
| 130¦~¾ú¥vªº°ª«~½è¼Ð·Ç¿z
¡@
ASTM
¼Ð·Ç¿zª½®|¥]¬A
100,200,300mm&3,8,10,18,^¦Tªº¿z¤l¥H¤Î¤Õ®|±q125mm-20µ¤§¤j¤p¤Ø¤oµ¥µ¥
¨Ì§÷½è¤À¬°¤£ÄÃù׿û¿zºô¡B»ÉÃ䤣Äÿû¿zºô¤Î»É¿zºô¤TºØ
¡@
¡@ |
| Tyler
¼Ð·Ç¿z |
| Wire
Mesh Series ASTM E11:87
|
| Designation |
Standard
¤½¨î³æ¦ì |
Mesh
NO.
(«Y»P¥ª¤è¤½¨î³æ¦ì¤@Pªº) |
»ù®æ
£X8"
or 200 mm |
|
125mm
106mm
100mm
90mm
75mm
63mm
53mm
50mm
45mm
37.5mm
31.5mm
26.5mm
25.0mm
22.4mm
19.0mm
16.0mm
13.2mm
12.5mm
11.2mm
9.5mm
8.0mm
6.7mm
6.3mm
5.6mm
4.75mm
4.00mm
|
5.00 in.
4.24 in.
4 in.
3 1/2 in.
3 in.
3 1/2 in.
2.12 in.
2 in.
1 3/4 in.
1 1/2 in.
1 1/4 in.
1.06 in.
1 in.
7/8 in.
3/4 in.
5/8 in.
.530 in.
1/2 in.
7/16 in.
3/8 in.
5/16 in.
.265 in.
1/4 in.
No.3 1/2
No.4
No.5
|
NT$ 2,700
(»É®Ø¤£Äÿû©³)
NT$ 2,970
(¥þ¤£Äÿû)
|
3.35mm
2.80mm
2.36mm
2.00mm
1.70mm
1.40mm
1.18mm
1.00mm
|
No.6
No.7
No.8
No.10
No.12
No.14
No.16
No.18
|
NT$ 2,700
(»É®Ø¤£Äÿû©³)
NT$2,970
(¥þ¤£Äÿû) |
3.35mm
2.80mm
2.36mm
2.00mm
1.70mm
1.40mm
1.18mm
1.00mm
|
No.6
No.7
No.8
No.10
No.12
No.14
No.16
No.18
|
NT$ 2,700
(»É®Ø¤£Äÿû©³)
NT$ 2,970
(¥þ¤£Äÿû) |
850 microns
710 microns
600 microns
500 microns
425 microns
355 microns
300 microns
250 microns
212 microns
180 microns
150 microns
125 microns
106 microns
90 microns
|
No.20
No.25
No.30
No.35
No.40
No.45
No.50
No.60
No.70
No.80
No.100
No.120
No.140
No.170
|
NT$ 2,700
(»É®Ø¤£Äÿû©³)
NT$ 2,970
(¥þ¤£Äÿû) |
75 microns
63 microns
|
No.200
No.230
|
NT$
3,680
(»É®Ø¤£Äÿû©³) |
NT$
4,180
(¥þ¤£Äÿû) |
|
| 53
microns
|
No.270
|
NT$
4,000
(»É®Ø¤£Äÿû©³) |
NT$
4,730
(¥þ¤£Äÿû) |
|
| 45
microns
|
No.325
|
NT$
5,200
(»É®Ø¤£Äÿû©³) |
NT$
5,500
(¥þ¤£Äÿû) |
|
| 38
microns |
No.400
|
NT$
6,600
(»É®Ø¤£Äÿû©³) |
NT$
6,930
(¥þ¤£Äÿû) |
|
| 32
microns
|
No.450
|
NT$
8,800
(»É®Ø¤£Äÿû©³) |
NT$
9,240
(¥þ¤£Äÿû) |
|
| 25
microns
|
No.500
|
NT$
16,200
(»É®Ø¤£Äÿû©³) |
NT$
16,500
(¥þ¤£Äÿû) |
|
| 20
microns
|
No.635
|
NT$
16,300
(»É®Ø¤£Äÿû©³) |
NT$
19,800
(¥þ¤£Äÿû) |
|
|
 |
Gold Series Test Sieves are
fabricated using a fine mesh screen cloth
produced to extraordinary "tight"
tolerances. The product assures the user,
the permissible variation of the average
openings of the instrument will be one-half
(50%) of the allowable ASTM or ISO
specifications. The Gold Series products are
available in stainless steel frames and
cloth, on a "Special" basis, and
sell at premium prices. (USA No. 20 through
500).
|
- Made in stainless/stainless
construction
- Designed as "masters" for
internal quality assurance programs.
- 8" diameter
- Each test Sieve is optically examined,
sterilized and supplied with complete
traceable documentation, including
information on actual opening sizes.
|
|
¡@ |
|
|
- Made in stainless/stainless construction
- For use with air jet sieving systems, 200 mm
Diameter frame, with rubber seal.
- Overall Height - 1-3/4"
- Depth to Cloth - 1-1/8"
|
|
¡@ |
The kit has been specifically
designed for use with the W. S. Tyler Ro-Tap sieve
shaker. There are some materials which, when tested
dry, produce less than accurate particle analysis
results.
If the material is not soluble in water and
reproducible results are difficult to obtain, then
wet testing may be the method required to produce
accurate data.
Special design, deep frame sieves have been
available for "hand" wet testing when the
applications have called for testing particles of
one size. However, in some tests, the application
requires analysis at a number of particle size
specifications.
Our new Wet Test Kit allows the user to take
advantage of the benefits and accuracy of mechanical
sieving when a "stack" of sieves is to be
used. Included in the kit package is all the
necessary equipment to convert a standard Ro-Tap
into a wet testing station (the kit does not include
a shaker).
|
|
 |
The W. S. Tyler Sound
Enclosures are designed to be used exclusively with
the Tyler Ro-Tap® Sieve Shakers. The
enclosures accommodate the Ro-Tap®'s,
RX-29/RX-30 and RX-94.
The sturdy cabinets are fabricated with 18 gauge
steel and supplied complete with a 1" metal
faced, acoustic foam, inner liner.
Operating noise levels of the Tyler Ro-Tap®
is reduced from approximately 85 dB (A) to 60 dB (A)
with use of the Sound Enclosures. |
|


¡@ ¡@ ¡@ ¡@ ¡@ ¡@ ¡@ ¡@ ¡@ |
| «¬¸¹ |
SS-50 |
SS-100 |
| ³W®æ |
¶}¤f
1/2" |
¶}¤f
1" |
| ¤Ø¤o
cm |
28W/33D/34H |
31W/14D/41H |
| «¶q |
3
lbs |
6
lbs |
¡@
| Sample Splitters are designed
to reduce or half the original sample size and
maintain representative size distribution. Sample
splitters are made of corrosion, abrasion
resistant steel in two widths, 1/2" (Model
SS-50) or 1" (Model SS-100). |
| Specifically designed to
decrease samples to workable testing sizes, the
sample reducer accurately maintains representative
particle size distribution. With one pour into the
feed hopper, material is reduced 16 times as it
travels throughout its geometrically designed
pattern. |
|
|
| Strong wooden handles lie
atop both W. S. Tyler's quality cleaning brushes.
We offer a soft nylon bristle brush for fine sieve
apertures, 200 mesh and finer, and a brass bristle
brush for more coarse openings. |
|
|

|
¼Æ¦ì¦¡·n¿z¾÷EML
200 T«¬
n
¾A¥Î¿zºô¤Ø¤o¡G3¡¨
(76.2 mm), 100 mm, 150 mm,
200 mm, 8¡¨ (203 mm)
n
¦Û§Ú½Õ¾ã´T«×
n
forced
regulated three¡@dimensional
sieving action
n
¥þ¥\¯à¹q¤l±±¨î»P¼Æ¦ìÅã¥Ü
n
saving
function for 10 sieving programs
n
²©ö±ªO«ö¶s¾Þ§@
n
¹qºÏÅX°Ê¦¡
n
¨C¤ÀÄÁ3000
Âà (50 Hertz)
n
¥i¶¡·² ©Î
³sÄò¹BÂà
n
¿zºô¥[¼Ë«~³Ì°ª¥i©Ó¨ü¦Ü8.7
KG
n
(±Nªñ©ó3
KG¼Ë«~)
n
¯Ó¹q¶q¡G230
V, 50-60 Hz oder 110 V, 50-60 Hz
n
®¶´T¡G¦Û§Ú½Õ¾ã¡A³Ì¤j¬ù3.0mm
n
¨Ï¥Î³]©w®É¶¡:
0-99 ¤ÀÄÁ©Î«ùÄò¨Ï¥Î
n
¯Ó¥\²v¡G185
Vol
n
«¶q¡G¬ù34
KG
n
¹B§@µ¶q:
78 dBA
|
|

|
¹qºÏ¦¡·n¿z¾÷
Model E8¡¨«¬
n
forced regulated three dimensional sieving action
n
¥þ¹q¤l¤Æ±±¨î
n
²©ö±ªO«ö¶s¾Þ§@
n
¹qºÏÅX°Ê¦¡
n
¨C¤ÀÄÁ3000Âà
(50 Hertz)
n
¥i¶¡·²¹BÂà
n
³Ì¤j¥i¨Ï¥Î¥~®|203
mm¿zºô
n
¿zºô¥[¼Ë«~³Ì°ª¥i©Ó¨ü¦Ü8.7
KG
(±Nªñ©ó3
KG¼Ë«~)
n
¯Ó¹q¶q¡G230
Volt, 50-60 Hertz or 110 Volt 50 ¡V 60 Hertz
n
¾_´T¡G¨â¬G©w¨BÆJ¡A¥i¦Û§Ú½Õ¾ã
n
¨Ï¥Î³]©w®É¶¡¡G0-99
¤ÀÄÁ©Î«ùÄò¨Ï
n
¯Ó¥\²v¡G185
Voltampère
n
¹B§@µ¶q¡G78
dBA
n
«¶q¡G¬ù34
KG
|